0.98 (2017-07-29)
-----------------
--common
* fix hardware initialization issue(always red led indicator) when power on
* improve move operations of cursors/label/trigger level, support both press-drag and select-move-release mode
* update the manually, and integrate into the menu of the software
* improve the content of 'About' menu, add 'changelogs' information
* firmware/HDL update
--for logic analyzer
* improve display scale of decoder contents under exception case
* fix display issue of progressbar of saving dsl file, when sample depth greater than 4G
* fix export issue when part of channels enabled
* fix pattern search issue.
* fix out of boundary issue of scroll bar, when sample depth greater than 8G
--for oscilloscope
* fix auto calibration issue
* improve noise processing method
0.97 (2017-06-02)
-----------------
--common
* fix file save fail issue
* fix window missing issue when disconnect external monitor
* fix crash issue when open illegal files
* improve graphics rendering and operations fluency
* fix window display issue: maximize/minimize/show/hide...etc
--for logic analyzer
* Enhance stream mode function to achieve 100M@3channels / 50M@6channels / 25M@12channels / 20M@16channels
* improve memory structure, extend sample depth to solve memory alloc fail issue
* resolve the coupling between channel data, unused channels don't occupy memory space
* add stop options to support upload already captured data under buffer mode
* add save/load function for protocol settings
* add cursor-based edge statistics function
* add repetitive mode to support repeat trigger acquisition
* improve search function to support start position setting
* improve advanced trigger
* improve cursor measurement method, add 16 sets of measurement between cursors
* fix trigger issue when sample rate greater than 100MHz
* fix display issue of trigger position
* implement free combination of channels under stream mode
* improve file saving display window, and add cancel button
* fix partial decoding issue
* fix messy code issue when adding protocol decoder
* improve the stability of protocol decoder
* add mapping function from graphic decode to list decode
* add mapping flag between graphic decode and list decode
* add channel height option for file device
* add auto snap to edge function when insert cursor
--for oscilloscope
* fix dsl file loading issue
* fix waveform delay display issue after trigger
* fix crash issue when enable/disable channels
* fix vertical position moving issue under stop state
* fix window background rendering issue
0.96 (2016-08-12)
-----------------
--common
* change color matching of UI
* fix memory leakage issues
* improve stability of usb transfer
* add new hardware support
* improve interaction of mouse operations
* improve stability of multi-thread operations
* change usb driver under windows system
* add path memory for file operations
* custom windows title of UI
* change path of setting files, avoid authority issues
--for logic analyzer
* add list viewer for results of protocol decoders
* add search function for protocol list viewer
* add file export for results of protocol decoders
* improve speed and memory usage of protocol decoders
* improve protocol decoders scripts (i2c, uart, spi already done)
* add start and end settings for protocol decoders
* improve serial trigger, add counter for serial value
* improve display and settings for protocol decoders
* add display of trigger time
* add multi-row search for protocol list viewer
* add trigger position and time for file save
--for oscilloscope
* add FFT function for signal analyzer
* add auto/trigger shift function
* improve zero adjustment program
* add manual zero adjustment
* add gain adjustment for each vdiv
* fix signal display issue when resize window
* fix crash issue when change measure settings
* fix run-without-display issue
* add trigger sensitivity setting
* add display of trigger status
* fix measure setting reset issue
0.95 (2015-12-14)
-----------------
--for logic analyzer
* add RLE compress mode
* improve mode setting strategy, fix channel number
* add edge count function
* fix memory leakage when running protocol decoder
* add signal height setting, improve display issue
* fix crash issue when adding group signal
* fix channel enable/disable issue
* fix channel display issue when load file input
* add cursor by mouse double-click
* fix other issues
--for oscilloscope
* add file export/load function
* fix wait time issue when trigger set
* improve display of signal measure
* add Vrms/Vmean/Vp-p measure
* fix setting issue when loading session
* improve add/del of measure ruler
* fix other issues
0.94 (2015-06-29)
-----------------
* add session load/store function
* add drag-and-drop effect in viewport window
* improve display effect of dock windows, add scroll bar
* fix other GUI issues
--for logic analyzer
* upgrade advance trigger counter from 16bit to 32bit
* add serial trigger function
* fix memory leakage issue when loading *.dsl files
* fix delete group signal issue when no data captured
--for oscilloscope
* add measurement of width, period, frequency and duty cycle
* fix instant capture issue @ demo mode
* add trigger hold-off time function
* fix channels enable/disable issue
* fix data error issue of instant capture before normal capture
* fix trigger position issue when only one channel enabled
* fix trigger level can't be changed issue when only one channel enabled
0.93 (2015-05-08)
-----------------
* Upgrade to qt5 library
* Support stdc++11
* Improve measure function @ LA mode
* Add duty cycle measure @ LA mode
* Fix out of range issue @ LA mode
* Add export function, support csv/vcd/gnuplot/zip @ LA mode; and csv @ DSO mode
* Add x1/x10/x100 probe options @ DSO mode
* Add measure function @ DSO mode
* Add voltage display of trigger value @ DSO mode
* Fix wave disappear issue @ DSO mode
* Fix trigger issue @ DSO stream mode
* Fix data repeat when set trigger @ LA stream mode
* Keep channel settings when reload occurred @ LA mode
* Fix decoder issue when capture part of data @ LA mode
* Fix stack decoder add issue @ LA mode
* Fix other bugs
0.92 (2015-04-15)
-----------------
* Add DSLogic Pro and DSCope support
* Add Stream mode to DSLogic & DSLogic Pro
* Support up to 1G samples @ LA mode
* Add zero adjustment @ Oscilloscope mode
* Support zero skew parameters restore
* Enhance stability
* Fix other bugs
0.4 (2014-09-24)
-----------------
* Add protocol decoders (38) support
* Improve the hardware configuration under various platforms
* Add different thresholds support
* Add options for input filter under logic analyzer mode
* Add instant capture(trigger ignore) under logic analyzer mode
* Ad detail capture status display under logic abrary
* Support stdc++11
* Improve measure function @ LA mode
* Add duty cycle measure @ LA mode
* Fix out of range issue @ LA mode
* Add export function, support csv/vcd/gnuplot/zip @ LA mode; and csv @ DSO mode
* Add x1/x10/x100 probe options @ DSO mode
* Add measure function @ DSO mode
* Add voltage display of trigger value @ DSO mode
* Fix wave disappear issue @ DSO mode
* Fix trigger issue @ DSO stream mode
* Fix data repeat when set trigger @ LA stream mode
* Keep channel settings when reload occurred @ LA mode
* Fix decoder issue when capture part of data @ LA mode
* Fix stack decoder add issue @ LA mode
* Fix other bugsnalyzer mode
* Add quick button for mode shift
* Redesign the GUI for oscilloscope
* Add flexible sample rate support under oscilloscope mode
* Fix trigger value setting issue
* Improve trigger method under oscilloscope mode
* Add shortcut keys for major operations
* Fix other bugs
0.3 (2014-06-29)
-----------------
* Add DSLogic Oscilloscope module support.
* Fix data display issue when not all channels are enabled.
* Fix issue of data mirrored to other channels.
* Fix radiobutton/checkbox display issue under certain windows theme.
* Add new simple trigger type
* Fix bugs of trigger setting and detection
* Fix other minor issues.
* Clean up the git repository
0.2.1 (2014-05-08)
------------------
* Add wireless extension hardware support.
* Fix libusb_error_io issue on Linux when sample rate >= 100MHz.
* Fix channel enable/disable bug.
* Fix device options config issue.
* Fix some display issues of UI.
0.2.0 (2014-04-13)
------------------
* Add DSLogic hardware support.
0.1.0 (2013-12-15)
------------------