2022-03-13 23:32:01 -07:00
.. _rb_bmc_gecko:
========================
Gecko BMC register block
========================
The Gecko BMC register block has a header with type 0x0000C141, version 0x00000100, and contains control registers for the Silicom Gecko BMC.
.. table::
======== ============= ====== ====== ====== ====== =============
Address Field 31..24 23..16 15..8 7..0 Reset value
======== ============= ====== ====== ====== ====== =============
RBB+0x00 Type Vendor ID Type RO 0x0000C141
-------- ------------- -------------- -------------- -------------
RBB+0x04 Version Major Minor Patch Meta RO 0x00000100
-------- ------------- ------ ------ ------ ------ -------------
RBB+0x08 Next pointer Pointer to next register block RO -
-------- ------------- ------------------------------ -------------
RBB+0x0C Status Status Read data RO 0x00000000
-------- ------------- -------------- -------------- -------------
RBB+0x10 Data Write data RW 0x00000000
-------- ------------- ------------------------------ -------------
RBB+0x14 Command Command RW 0x00000000
======== ============= ============== ============== =============
See :ref:`rb_overview` for definitions of the standard register block header fields.
.. object:: Status
The status field provides status information and the read data from the BMC.
.. table::
======== ====== ====== ====== ====== =============
Address 31..24 23..16 15..8 7..0 Reset value
======== ====== ====== ====== ====== =============
RBB+0x0C Status Read data RO 0x00000000
======== ============== ============== =============
.. table::
=== ========
Bit Function
=== ========
16 Done
18 Timeout
19 Idle
=== ========
.. object:: Data
The data field provides the write data to the BMC.
.. table::
======== ====== ====== ====== ====== =============
Address 31..24 23..16 15..8 7..0 Reset value
======== ====== ====== ====== ====== =============
RBB+0x10 Write data RW 0x00000000
======== ============================== =============
.. object:: Command
The command field provides the command to the BMC. Writing to the command field triggers an SPI transfer to the BMC.
.. table::
======== ====== ====== ====== ====== =============
Address 31..24 23..16 15..8 7..0 Reset value
======== ====== ====== ====== ====== =============
RBB+0x14 Command RW 0x00000000
======== ============== ============== =============