-adding reset signals to synchronizer to solve startup issues
-setting config in test bench for speedup, default reg config now correct
-fix (my) stupid bug in etx_arbiter
-adding reset to fifo (todo: review this!)
-reviewing "all red" from waveforms is a must. Red (x) on data is ok, but leaving them on control signals is asking for trouble. Better safe than sorry when it comes to reset.
-added register read/write properly
-removed redundant wrapper layers in maxi/saxi
-changed over to "emesh" interface from packet 103 bit data
-cleaned up maxi
-cleaned up saxi
-removed redundant signals in elink interface (user,lock,..)
-added wrapper to fifo (to carry emesh interface through)
Now comes the fun part of testing
Our "standard packet" order should be followed everywhere to ease verification and integration (standards are good fir reuse...):
[0]=access
[1]=write
[3:2]=datamode
[7:4]=ctrlmode
[39:8]=dstaddr
[71:40]=data
[103:72]=upper-data (or srcaddr)